Product overview: Fluke 101 Digital Multimeter
Designed for basic electrical tests, the Fluke 101 digital multimeter offers reliable measurements for residential/commercial electricians and heating and air conditioning technicians. This small, lightweight multimeter fits comfortably in your hand but is rugged enough to withstand daily use for years to come. When it comes to professional-grade affordable multimeters, the Fluke 101 digital multimeter is your best choice.
Key features
Basic dc accuracy 0.5%
CAT III 600 V safety rated
Diode and continuity test with buzzer
Small lightweight design for one-handed use
Rugged, durable design
Automatic shutdown
Battery is easy to replace
Specifications: Fluke 101 Digital
Multimeter |
||
Electrical Specifications |
||
V AC (40-500Hz) |
Range |
600.0 mV |
|
Resolution |
0.1 mV |
|
Accuracy |
3.0%±3 digit |
V DC |
Range |
6.000 V |
|
Resolution |
0.001 V |
|
Accuracy |
0.5%±3 digit |
Resistance Ohms |
Range |
400.0 Ω |
|
Resolution |
0.1 Ω |
|
Accuracy |
0.5 %±3 digit |
Capacitance |
Range |
50.00 nF |
|
Resolution |
0.01 nF |
Frequency |
Range |
50.00 Hz |
|
Resolution |
0.01 Hz |
Duty Cycle |
Range |
0.1 % to 99.9 % |
|
Resolution |
0.10% |
General Specifications |
|
CAT Rating |
CAT III 600 V |
V AC Range |
600.0 V |
V DC Range |
600.0 V |
Ohms Range |
40.00 MΩ |
Auto Shutoff |
Y |
Continuity |
Y |
Capacitor |
100.0 μF |
Frequency |
100.0 kHz |
Hold |
No |
Duty Cycle |
Yes |
Size |
130 mm x 65 mm x 27mm |
Weight |
160 g |
Battery |
Two AAA |
Warranty |
1 year |
Environmental Specifications |
|
Operating Temperature |
0 °C to +40 °C |
Storage Temperature |
-30 °C to +60 °C |
Operating Humidity |
Non condensing (<10 °C) |
Operating Humidity, 40 MΩ |
80% RH 10 °C to 30 °C, 70% RH 30 °C
to 40 °C |
Operating Altitude |
2,000 meters |
Storage Altitude |
12,000 meters |
IP Rating |
IP 40 per IEC 60529 |
Vibration Requirements |
MIL-PRF-28800F, Class 2 |
Drop Test Requirements |
-10°C and 1 meter to surface, per
IEC-61010-1, and Fluke SOP 39.1 for portable Hand-held equipment |
|
Shipping container drop per Fluke SOP
39. |
EMI, RFI, EMC |
Must meet all applicable requirements
in |
Absorption/Corrosion |
Per Fluke SOP 39.1 |
Temperature Coefficients |
Add 0.1 x specified accuracy for each
degree C above 28 °C or below 18 ºC |